Is two better than one? Muscle vibration plus robotic rehabilitation to improve upper limb spasticity and function: A pilot randomized controlled trial

  • Rocco Salvatore Calabrò ,

    Contributed equally to this work with: Rocco Salvatore Calabrò, Antonino Naro

    Roles Conceptualization, Supervision, Validation, Writing – review & editing

    salbro77@tiscali.it

    Affiliation IRCCS Centro Neurolesi “Bonino-Pulejo” Messina; Messina, Italy

  • Antonino Naro ,

    Contributed equally to this work with: Rocco Salvatore Calabrò, Antonino Naro

    Roles Conceptualization, Data curation, Formal analysis, Methodology, Writing – original draft

    Affiliation IRCCS Centro Neurolesi “Bonino-Pulejo” Messina; Messina, Italy

  • Margherita Russo,

    Roles Data curation, Investigation, Visualization

    Affiliation IRCCS Centro Neurolesi “Bonino-Pulejo” Messina; Messina, Italy

  • Demetrio Milardi,

    Roles Data curation, Formal analysis, Methodology

    Affiliations IRCCS Centro Neurolesi “Bonino-Pulejo” Messina; Messina, Italy, Department of Biomedical, Dental Sciences, and Morphological and Functional Images, University of Messina; Messina, Italy

  • Antonino Leo,

    Roles Data curation, Formal analysis, Visualization

    Affiliation IRCCS Centro Neurolesi “Bonino-Pulejo” Messina; Messina, Italy

  • Serena Filoni,

    Roles Conceptualization, Methodology, Validation

    Affiliation Fondazione Centri di Riabilitazione Padre Pio Onlus; San Giovanni Rotondo, Italy

  • Antonia Trinchera,

    Roles Data curation, Formal analysis, Validation

    Affiliation IRCCS Centro Neurolesi “Bonino-Pulejo” Messina; Messina, Italy

  • Placido Bramanti

    Roles Project administration, Resources, Writing – review & editing

    Affiliation IRCCS Centro Neurolesi “Bonino-Pulejo” Messina; Messina, Italy

Abstract

Even though robotic rehabilitation is very useful to improve motor function, there is no conclusive evidence on its role in reducing post-stroke spasticity. Focal muscle vibration (MV) is instead very useful to reduce segmental spasticity, with a consequent positive effect on motor function. Therefore, it could be possible to strengthen the effects of robotic rehabilitation by coupling MV. To this end, we designed a pilot randomized controlled trial (Clinical Trial NCT03110718) that included twenty patients suffering from unilateral post-stroke upper limb spasticity. Patients underwent 40 daily sessions of Armeo-Power training (1 hour/session, 5 sessions/week, for 8 weeks) with or without spastic antagonist MV. They were randomized into two groups of 10 individuals, which received (group-A) or not (group-B) MV. The intensity of MV, represented by the peak acceleration (a-peak), was calculated by the formula (2πf)2A, where f is the frequency of MV and A is the amplitude. Modified Ashworth Scale (MAS), short intracortical inhibition (SICI), and Hmax/Mmax ratio (HMR) were the primary outcomes measured before and after (immediately and 4 weeks later) the end of the treatment. In all patients of group-A, we observed a greater reduction of MAS (p = 0.007, d = 0.6) and HMR (p<0.001, d = 0.7), and a more evident increase of SICI (p<0.001, d = 0.7) up to 4 weeks after the end of the treatment, as compared to group-B. Likewise, group-A showed a greater function outcome of upper limb (Functional Independence Measure p = 0.1, d = 0.7; Fugl-Meyer Assessment of the Upper Extremity p = 0.007, d = 0.4) up to 4 weeks after the end of the treatment. A significant correlation was found between the degree of MAS reduction and SICI increase in the agonist spastic muscles (p = 0.004). Our data show that this combined rehabilitative approach could be a promising option in improving upper limb spasticity and motor function. We could hypothesize that the greater rehabilitative outcome improvement may depend on a reshape of corticospinal plasticity induced by a sort of associative plasticity between Armeo-Power and MV.

Introduction

Spasticity is defined as a velocity-dependent increase in muscle tone due to the hyper-excitability of muscle stretch reflex [1]. Spasticity of the upper limb is a common condition following stroke and traumatic brain injury and needs to be assessed carefully because of the significant adverse effects on patient’s motor functions, autonomy, and quality of life [2].

Different pharmacological and non-pharmacological approaches are currently available for upper limb spasticity management, as physiotherapy (including magnetic stimulation, electromagnetic therapy, sensory-motor techniques, and functional electrical stimulation treatment) and robot-assisted therapy [34]. In this regard, several studies suggest robotic devices, including the Armeo® (a robotic exoskeleton for the rehabilitation of upper limbs), may help reducing spasticity by modifying spasticity-related synaptic processes at either the brain or spinal level [513], resulting in spasticity reduction in antagonist muscles through, e.g., a strengthening of spinal reciprocal inhibition mechanisms [11].

Growing research is proposing segmental muscle vibration (MV) as being a powerful tool for the treatment of focal spasticity in post-stroke patients [1415]. Mechanical devices deliver low-amplitude/high-frequency vibratory stimuli to specific muscles [1617], thus offering strong proprioceptive inputs by activating the neural pathway from muscle spindle annulospiral endings to Ia-fiber, dorsal column–medial lemniscal pathway, the ventral posterolateral nucleus of the thalamus (and other nuclei of the basal ganglia), up to the primary somatosensory area (postcentral gyrus and posterior paracentral lobule of the parietal lobe), and the primary motor cortex [1819]. At the cortical network level, proprioceptive inputs can alter the excitability of the corticospinal pathway by modulating intracortical inhibitory and facilitatory networks within primary sensory and motor cortex, and affecting the strength of sensory inputs to motor circuits [2022]. In particular, periods of focal MV delivered alone can modify sensorimotor organization within the primary motor cortex (i.e., can increase or decrease motor evoked potential—MEP—and short intracortical inhibition (SICI) magnitude in the vibrated muscles, while opposite changes occur in the neighboring muscles), thus reducing segmental hyper-excitability and spasticity [2022].

While focal MV is commonly used to reduce upper limb post-stroke spasticity, there is no conclusive evidence on the role of robotic rehabilitation in such a condition [1417,2327]. A strengthening of the effects of neurorobotics and MV on spasticity could be achieved by combining MV and neurorobotics. The rationale for combining Armeo-Power and MV to reduce spasticity could lie in the summation and amplification of their single modulatory effects on corticospinal excitability [28]. Specifically, it is hypothesizable that MV may strengthen the learning-dependent plasticity processes within sensory-motor areas that are in turn triggered by the intensive, repetitive, and task-oriented movement training offered by Armeo-Power [2930]. Such an amplification may depend on a sort of associative plasticity (i.e., the one generated by timely coupling two different synaptic inputs) between MV and Armeo-Power [3133].

To the best of our knowledge, this is the first attempt to investigate such approach. Indeed, a previous study combining MV with conventional physiotherapy used Armeo only as evaluating tool [14].

The aim of our study was to assess whether a combined protocol employing MV and Armeo-Power training, as compared to Armeo-Power alone, may improve upper limb spasticity and motor function in patients suffering from a hemispheric stroke in the chronic phase. To this end, we compared the clinical and electrophysiological after-effects of Armeo-Power with or without MV on upper limb spasticity. We also assessed the effects on upper limb motor function and muscle activation, disability burden, and mood, given that spasticity may have significant negative consequences on these outcomes. Further, it is important to evaluate mood, as it may negatively affect functional recovery [3436], increase mortality [37], and weaken the compliance of the patient to the rehabilitative training [3839].

Materials and methods

Design

We consecutively included all the eligible patients affected by stroke who were attending the Neurorobotic Rehabilitation Laboratory of the IRCCS Centro Neurolesi “Bonino-Pulejo” (Messina, Italy), from January 2015 to June 2015 (Clinical Trial: NCT03110718). See S1 and S2 Files for trial study protocol.

The study was designed as a pilot randomized controlled trial using a double-blind, parallel-group study design. The enrolled patients were randomly assigned to receive Armeo-Power paired with real MV (group-A) or Armeo-Power with sham MV (group-B) using an automated computer randomization program. The patients, the clinical assessors (who were different from the physiotherapist who managed Armeo-Power and MV), and the statisticians (who differed from the clinical assessors) were blinded to group allocation.

Twenty patients were included in this pilot study according to inclusion criteria as follows: a first ever supra-tentorial unilateral (left hemisphere) ischemic stroke experienced more than 3 months before the enrollment; a deficit of shoulder abductor, arm flexor, and elbow extensor muscles ranging from 2 to 4 on the Medical Research Council scale [4041]; a spasticity of biceps brachii, pectoralis major, and latissimus dorsi (namely, spastic agonist muscles) ranging from 1+ to 3 on the Modified Ashworth Scale (MAS) [4243]; ages between 50 and 80 years old; and Caucasian ethnicity. We excluded the patients who had history of concomitant neurodegenerative diseases or brain surgery; severe cognitive or language impairment; systemic, bone, or joint disorders; changes in central or peripheral sensitivity; concomitant use of drugs for spasticity; or contraindications to transcranial magnetic stimulation (TMS). CONSORT flowchart is reported in Fig 1; see S1 Table for CONSORT checklist.

The Local Ethics Committee approved the study and the procedures for gaining consent (study number registration 43/2013), and all the participants gave their written informed consent to the study. In comparison to the original trial study protocol (see supporting information), we lengthened the duration and number of rehabilitative sessions, and the epochs of assessment of clinical and electrophysiological outcomes, which were adapted to the aims and scope of the present pilot randomized clinical trial.

Interventions

The Armeo-Powera is a robotic, ergonomic arm exoskeleton for rehabilitation that cradles the entire arm, from shoulder to the hand (thus allowing intensive, repetitive, and task-oriented training of shoulder, elbow, wrist, and grasping movements) and counterbalances the weight of the patients’ arm thanks to a gravity-support system (offered by the arm exoskeleton). Armeo-Power allows the treatment of motor function impairment by enhancing any residual function and neuromuscular control, assisting active movement across a large 3D workspace, and providing augmented feedback [58,44].

All the patients underwent a daily Armeo-Power training session lasting about one hour, scheduled five times a week for eight consecutive weeks (for a total of 40 sessions). During the first session, the device was adjusted to the patient’s arm size and the angle of suspension. The working space and the exercises were selected once the upper limb had been fitted with the system. Subjects performed repetitively a customized group of exercises under the supervision of a skilled physiotherapist. Such exercises required all the available arm and elbow movements to improve shoulder abduction, arm flexion, and elbow extension (e.g., to parry penalties, collect drops of water with a cup, take the apples and place them in the shopping cart, clean surfaces, clean the stove, and break an egg into the pan). Device guidance force and arm weight support were individually adapted during the Armeo-Power training. The device automatically recorded information about the exercise (including the scheduled difficulty level, the score obtained, the time required to perform the exercise, the force exerted by the patient, and the passive and active range of movement).

All the subjects assigned to group-A received a focal belly MV on the spastic antagonist muscles (i.e., triceps brachialis, supraspinatus, and deltoid) during shoulder abduction and elbow extension (Fig 2).

MV was delivered by a pneumatic vibrator powered by compressed airb, and wired to probes with appropriate muscle diameter (up to 2cm2). The intensity of MV, represented by the peak acceleration (a-peak), was calculated by the formula (2πf)2A, where f is the frequency of MV (set at 80 Hz) and A is the amplitude of vibration (i.e., of the peak-to-peak sinusoidal displacement of the underneath structures), which was individually adapted (0.3±0.1 mm) to be just below the threshold for perceiving an illusory movement. We chose such a set up to avoid any signs of muscle contraction potentially reflecting either possible voluntary movement or occurrence of the tonic vibration reflex. Sham MV intensity was set at the same frequency but at 0.1 mm below the individually adjusted amplitude for real MV. MV parameter were kept constant throughout the treatment.

Primary outcome measures

Patients were assessed at baseline (T0), directly after the neurorehabilitative training (T1), and after one month of rest from Armeo-Power training (T2) (during which the participants underwent a standard physical therapy treatment).

The primary outcomes consisted of the MAS from spastic agonist muscles (causing arm adduction, inward rotation, flexion, and forearm flexion), the SICI, and the Hmax/Mmax ratio (HMR).

The MAS measures spasticity, evaluating the resistance of a relaxed limb to a rapid passive stretch in six stages [4546]. A score of zero indicates a normal or slightly increased muscle tone, whilst five indicates a state in which the passive movement is impossible. We tested the abduction–adduction, the flexion–extension, the intrarotation–extrarotation of the shoulder, and the flexion and extension of the elbow.

SICI is a measure of cortical excitability, given that it probes intracortical GABAergic interneurons within the primary motor area. It is tested by quantifying the inhibitory effect of a TMS pulse (conditioning) preceding of few milliseconds that eliciting MEP (test stimulus). SICI is typically reduced (i.e., values going toward 100%) in spasticity, maybe because of a deteriorated interhemispheric inhibition following brain damage. There is a significant correlation between spasticity and SICI given that baclofen has been shown to reduce spasticity by increasing GABAergic inhibition [4748]. Consequently, one would expect a strengthening (i.e., a decrease) of intracortical inhibition when spasticity improves (i.e., the MAS score decreases).

HMR is commonly used to study the excitability of spinal motor circuitry. In particular, HMR represents the neurophysiological correlate of the function of spinal inhibitory interneurons and of the descending pathways impairment in spasticity [49]. HMR alterations are therefore associated with spasticity and correlate, although nonlinearly, with MAS scores [50]. A higher ratio suggests higher corticospinal excitability subtending spasticity.

In the present trial, the primary endpoint with respect to the efficacy of MV was the proportion of patients achieving a minimal detectable change (which is a statistical estimate of the smallest amount of change that can be detected by a measure, corresponding to a noticeable change in the measure) of approximately a one-point decrease on the MAS as reported in the literature [51]. This minimal detectable change also reflects a clinically important difference [51]. Concerning SICI and HMR, there are no data available on the minimal detectable change. Nonetheless, we found in our previous work on Armeo-Power that a decrease in SICI and HMR of at least 15% represents a noticeable change [13].

Secondary outcome measures

We measured the effects of training on the recovery in post-stroke hemiplegic patients as measured by Fugl-Meyer Assessment of the Upper Extremity (FMA-UE) [5253]. Each item of motor function for the upper limb is scored on a 3-point ordinal scale (0 = cannot perform, 1 = performs partially, and 2 = performs fully; the total score ranges from 0 to 66).

Disability burden was assessed by the Functional Independence Measure (FIM)[54], which provides a measure for disability based on the International Classification of Impairment, Disabilities and Handicaps. FIM measures the level of a patient's disability and indicates how much assistance is required for the individual to carry out activities of daily living. Beyond the total FIM score, we assessed some subitems, i.e., eating, grooming, bathing, upper body dressing, lower body dressing, and toileting, which are related to self-care mainly involving upper limb function [55]. Each task is rated on a 7-point ordinal scale that ranges from 1 = total assistance (or complete dependence) to 7 = complete independence.

We also assessed mood and anxiety by Hamilton Rating Scale for depression (HRS-D) and Hamilton Rating Scale for anxiety (HRS-A), which are multiple-item questionnaires used to provide an indication of depression and anxiety and as a guide to evaluate recovery [5659]. The higher the score, the more severe is the mood/anxiety impairment.

Kinematic properties of upper limb were quantified by measuring with the Armeo-Power device the passive range of movement (measured in degree) and the force (in Newton × meter) of the abduction–adduction, flexion–extension, intrarotation–extrarotation of the shoulder, and the flexion and extension of the elbow. Moreover, we measured the arm weight support offered by the Armeo-Power device to sustain the upper limb during exercise training and the device guidance force (that is, the assist-as-needed support provided by the robotic arm exoskeleton that automatically adapts the force exerted by the device itself to the patient’s capabilities to accomplish the movements required by the tasks (i.e., shoulder abduction, arm flexion, and elbow extension through different spaces).

Additionally, we measured the resting motor threshold (measured as % of TMS stimulator output) and the peak-to-peak MEP amplitude (in mV), which more broadly reflects the excitability of corticomotor projections during muscle relaxation [60] and the intracortical facilitation (ICF). This is a measure of cortical facilitation carried by interneurons within the primary motor cortex. Similar to SICI, some correlations have been found between spasticity and ICF, given that this is abnormally increased in pure spasticity [61]. Consequently, one would expect a weakening (i.e., a decrease) of ICF when spasticity improves (i.e., the MAS score decreases).

Finally, we quantified the root mean square value from the surface electromyography signals of all the vibrated (triceps brachialis, supraspinatus, and deltoid) and nonvibrated muscles (biceps brachii, latissimus dorsi, and pectoralis maior). Root mean square value quantifies and reflects the physiological activity in the motor unit during contraction, thus expressing a correlation between the contraction force and the root mean square value [62].

Transcranial magnetic stimulation

Primary motor cortex excitability at rest was tested through monophasic TMS pulses delivered by a figure-of-eight coil (with an external loop diameter of 9 cm) wired to a high-power Magstim200 stimulator 2 [63]. During the experiments, EMG activity was continuously monitored by visual- auditory feedback (i.e., an oscilloscope with loudspeakers, which was placed in front of the subject) to ensure complete muscle relaxation. We first determined the resting motor threshold from biceps brachii muscle [64]. Then, we delivered 15 supra-threshold monophasic pulses (120% resting motor threshold), and the mean amplitude was calculated. SICI and ICF were determined according to the paired-pulse method described by Kujirai and colleagues [64]. The intensity of the conditioning stimulus was set at 70% of resting motor threshold. The intensity of the test stimulus was 120% resting motor threshold. Stimulus intensities were kept constant across the blocks of measurement. SICI and ICF were assessed at an ISI of 2 and 12 ms, respectively [6571]. Fifteen trials were recorded for each ISI and randomly intermingled with 15 trials in which MEPs were elicited by the test stimulus alone. The peak-to-peak amplitude of the unconditioned MEP was taken as a measure of corticospinal excitability. Mean amplitude of the conditioned MEP was expressed as a percentage of the amplitude of the unconditioned MEP. The relative change in MEP amplitude induced by the conditioning stimulus characterized the strength of SICI and ICF.

Hmax/Mmax ratio

The H-reflex and M-wave were recorded in the affected arm while the subject lay prone on a gurney with the shoulder abducted to 90°, palm facing up with the elbow slightly flexed. Bipolar Ag-AgCl surface electrodes (Nicolet Biomedical, Maddison, Wisconsin, USA) were applied in a belly-tendon montage over the spastic biceps brachii. The H-reflex was identified as a triphasic wave with a small initial positive deflection followed by a larger negative one. The maximum amplitudes of the H-reflex and the M-wave were measured from the peak of the positive to the peak of the negative deflections. The HMR was calculated by dividing the maximum amplitudes of the H-reflex by that of the M-wave.

Surface electromyographic recording

Surface adhesive electrodes were applied on both vibrated and nonvibrated muscles, with a bipolar belly-tendon montage. Although the supraspinatus has not routinely been monitored through surface electrodes, a small window of access to the trapezius tendon exists (i.e., at the midpoint and two fingerbreadths superior to the scapular spine) [72]. In addition, we used a high-pass filtering [73], and the raw signals were amplified and filtered at 30–1000Hz (Neurolog System) (Digitimer Ltd, Welwyn Garden City, UK). Patients wore the robotic arm and were invited to align their upper limb to the scapular plane to the best of their ability, thus abducting, flexing, and extra-rotating the arm, and extending the elbow. The task was repeated 15 times. The subject had to perform such tasks without Armeo-Power support (i.e., the subject held only the weight of his arm). The electrical activity that is displayed in form of surface EMG signals is the result of neuromuscular activation associated with muscle contraction. The amplitude of EMG signal reveals is roughly proportional to the force exerted by the underlying muscle. To analyze the amplitude of surface EMG signal, we calculated the root mean square, that is the square root of average power of a signal for given period of time [74]. To this end, raw EMG data were full-wave rectified and processed using an algorithm with a 20 ms moving window. EMG with the greatest rectified and smoothed amplitude was quantified for a 2 sec period during each test. The data resulting from this period were utilized for analysis of each muscle test performed for normalization and each exercise.

Statistical analysis

Descriptive statistics are given as mean ± standard deviation (SD) or median. The Shapiro-Wilk statistic was used to test the normality of the distribution of all variables; electrophysiological and kinematic measures were normally distributed (p>0.2), whereas clinical measures showed a non-normal distribution (p<0.05). Therefore, parametric and nonparametric statistics were used to describe changes from baseline (T0) to post-treatment (T1 and T2). One-way analysis of variance (ANOVA) for repeated measures or the Friedman test were performed depending on normal or non-normal distribution of the data, respectively. A pair-wise comparison was performed using the Wilcoxon signed-rank test to identify significant difference across time. Repeated measure ANOVAs, followed by Bonferroni correction for multiple comparisons for post-hoc analysis, were used to examine differences between the groups (two levels: A and B) over time (three levels: T0, T1, and T2). Clinical-demographic characteristics (age, gender, disease duration, and localization of brain lesion at magnetic resonance imaging) and kinematic factors (body weight support and device guidance force) were added in the ANOVA as covariates. Descriptive analysis was used to evaluate the effect size measures between the two groups (Cohen's d calculation).

We measured the incidence of subjects (namely, “responder patients”) exceeding a decrement of at least 1-point at the MAS from T0 to T2 (i.e., a minimal detectable change at the 95% confidence interval, according to literature data) [5051] and a decrement of at least 15% at SICI and HMR (according to our previous work) [13]. To assess the difference between the two groups, we calculated the relative risk (RR) of an improvement when the patient is really treated with MV. A patient was considered improved when the minimal detectable change at T2 of the MAS score was a decrease of at least 1 point at the MAS and of at least 15% at the SICI and HMR (at the 95% confidence interval and according to the currently available data) [13,5051,75]. Finally, clinical-electrophysiological correlations were evaluated by Fisher’s exact test.

Statistical analyses were carried out using Statview software (version 5; SAS Institute Inc., Cary, NC).

Results

Twenty patients were recruited from January 2015 to June 2015. The recruitment was then stopped because all the patients who were treated at our rehabilitation unit had been evaluated to participate in the study. Baseline clinical-demographic characteristics (age, gender, disease duration, and localization of brain lesion at magnetic resonance imaging) were similar in both groups (Table 1).

thumbnail
Table 1. Clinical-demographic characteristics at baseline.

https://doi.org/10.1371/journal.pone.0185936.t001

All the patients showed a mild-to-severe upper limb motor impairment and disability burden, in parallel to low MEP amplitude and high SICI, ICF, and HMR values from the spastic biceps brachii (Table 2). Arm weight support and device guidance force were initially set at 40% and 80%, respectively, in both groups.

thumbnail
Table 2. Repeated results of primary clinical and electrophysiological outcomes.

https://doi.org/10.1371/journal.pone.0185936.t002

Primary outcomes

All the patients of group-A and three patients of group-B (30%) achieved the primary endpoint (namely, “responder patients”), i.e., a MAS reduction of at least 1 point and an HMR and SICI decrease of at least 15% (RR = 3.3; 95% confidence interval 1.29 to 8.59; p = 0.01). Primary outcome measures are summarized in Table 2. The repeated-measures analysis showed a significant interaction time×group for each primary outcome (p<0.001), thus indicating that there was a significant difference between the groups at T1 and T2.

The results show a significant reduction in MAS, SICI, and HMR at T1 and T2 only in group-A (p<0.001).

Concerning clinical-electrophysiological correlations (Fisher’s exact test), we observed that a greater decrease in MAS scoring was correlated to a greater SICI strengthening in the biceps brachii (Z = 2.8, p = 0.004).

Secondary clinical outcomes

The patients of group-A showed a more evident clinical improvement than group-B patients, with significant FIM six items and FMA-UE increase, and HRS-D and HRS-A decrease. Secondary clinical outcome measures are summarized in Table 3.

thumbnail
Table 3. Repeated results of secondary clinical and electrophysiological outcomes.

https://doi.org/10.1371/journal.pone.0185936.t003

The repeated-measures analysis showed a significant interaction time×group for the six items of FIM (p<0.001), FMA-UE (p = 0.003), HRS-D (p = 0.02), and HRS-A (p = 0.001), thus indicating that there was a significant difference between the groups at T1 and T2.

However, a significant increase in FIM, and a decrease in HRS-D and HRS-A was found only in the group-A (p<0.001). FMA-UE increased in the group-A at T1 and T2 (p<0.001), whereas it augmented in group-B only at T1 (p<0.001).

As additional data, we observed a reduction in flexion muscle synergies (couplings of shoulder elevation movements with elbow flexion) in favor of extension muscle synergies (shoulder adduction/internal-rotation with elbow extension) in all patients of group-A and three subjects of group-B.

Secondary electrophysiological outcomes

The patients of group-A showed a greater activation of vibrated muscles and a MEP amplitude increase than patients of group-B. Secondary electrophysiological outcome measures are summarized in Tables 3 and 4.

thumbnail
Table 4. Repeated results of secondary kinematic outcomes.

https://doi.org/10.1371/journal.pone.0185936.t004

The repeated-measures analysis showed a significant interaction time×group for MEP amplitude (p = 0.002) and root mean square magnitude of deltoids (p = 0.01) and supraspinatus (p<0.001), thus indicating that there was a significant difference between the groups at T1 and T2. In particular, we found an increase of MEP amplitude and root mean square magnitude of deltoids and supraspinatus only in the group-A at T1 and T2 (p<0.001). Instead, the magnitude of root mean square magnitude of triceps brachii increased in both groups at T1 and T2 (p<0.001)

The strength of ICF and the magnitude of root mean square magnitude of non-vibrated muscles showed no significant changes.

Secondary kinematic outcomes

The patients of group-A showed a greater kinematic amelioration (consisting of an increase in passive range of motion and force in shoulder abduction and adduction movements, and in reduced arm weight support and device guidance force) than the patients of group-B (Table 4). The repeated-measures analysis showed a significant interaction time×group for arm weight support (p<0.001), device guidance force (p = 0.006), and force (p<0.001) and passive range of movement (p<0.001) of shoulder abduction and adduction, thus indicating that there was a significant difference between the groups at T1 and T2.

Specifically, the increase of force and range of movement of shoulder abduction and adduction, and the decrease of arm weight support and device guidance force were significant in group-A at T1 and T2 (p<0.001), whereas such changes were significant in group-B only at T1. The remaining kinematic parameters showed no changes.

To investigate whether MAS change (as main primary outcome measure) induced by MV could be affected by arm weight support and device guidance force, we calculated an ANOVA using these factors as covariates. There were no interactions among arm weight support, device guidance force, and MV in both the groups (group×arm-weight-support×device-guidance-force p = 0.9).

Discussion

The data of our pilot study suggest the usefulness of focal MV when combined with robotic neurorehabilitation in managing upper limb spasticity in chronic stroke patients. In fact, MV induced a MAS decrease, paralleled by an HMR decrease and a SICI strengthening in all the patients of group-A, who thus achieved the primary outcome. Moreover, the MAS decrease correlated significantly with SICI potentiation. Finally, MV strengthened the amelioration of the other outcomes yielded by the Armeo-Power alone and determined a duration of Armeo-Power aftereffects up to 1 month, as compared to Armeo-Power delivered alone. Altogether, these data suggest that the improvement in spasticity (namely, MAS reduction) induced by the association between motor training and MV may depend on a modulation of motor cortex and spinal excitability, i.e., an increase of the inhibitory output from motor cortex to spinal level, as suggested by the SICI increase and the HMR decrease. In fact, Armeo-Power alone did not influence MAS, SICI, or HMR substantially (except in three patients). Nonetheless, we have to be cautious in interpreting our data concerning the efficacy of focal MV when combined with robotic neurorehabilitation, given the underpowered nature of the study. Although promising, our data ought confirmation by further large sample studies.

Putative mechanisms of spasticity reduction

There are some conflicting reports in the literature concerning the improvement in spasticity sustained by MV and Armeo-Power practiced alone [7677]. Our data suggest that MV combined with robotic neurorehabilitation may improve spasticity in post-stroke patients, probably in keeping with the principles of associative plasticity [912,23,3233]. In fact, MV allowed for boosting corticospinal excitability at both the cortical and spinal level (i.e., a clear modulation SICI and HMR) as compared to Armeo-Power delivered alone. These effects may depend on a direct entrainment of muscle spindle Ia-afferent firing up to 80Hz, which may be sensitive to MV protocol [1617]. Of note, we applied an intensity of vibration below the threshold for eliciting tonic vibratory reflex or inducing movements. This may have increased antagonist muscle activation and reduced agonist activation, probably by harnessing mechanisms of reciprocal inhibition, presynaptic inhibition, and changes in the intrinsic regulation of transmitter release from the Ia-afferents of spastic muscles at spinal level, besides variations of the intrinsic biomechanical and electrophysiological properties of the target muscles [2327,33]. Nonetheless, some studies have shown that MV of spastic agonist muscle also led to a spasticity decrease, probably owing to post-activation depression phenomena, an increase of reflex threshold, or a co-contraction decrease [7880]. In addition, MV effects may also depend on the characteristics of the MV device itself [2327,33].

The amount of proprioceptive information from muscle and joint receptors that reaches the sensory-motor cortices during MV may also have an important role [22]. Indeed, the MV of antagonist muscles led to a primary motor cortex excitability increase and SICI potentiation in biceps brachii muscle (i.e., spastic agonist muscle). These findings agree with previous functional neuroimaging studies suggesting that MV activates primary sensory and motor areas (beyond premotor, supplementary motor, and cingulate cortices) [81]. Hence, in analogy with premotor-motor facilitation, the effects on SICI could depend on a modulation of bidirectional connections linking premotor and motor cortices sustaining MEP amplitude increase.

Notably, the Armeo-Power also offers a considerable amount of sensory input. In fact, it has been demonstrated that primary motor cortex and supplementary motor area are activated during a sensory stimulation using passive cyclical joint movements [82]. However, these passive movements activate the joint and cutaneous receptors more than the Ia-afferents, which are essential for primary motor cortex proprioceptive activation [8384]. Thus, the prominent involvement of Ia-afferents could account for the stronger modulation of primary motor cortex excitability following the Armeo-Power paired with real MV in comparison to the Armeo-Power paired with sham-MV. In addition, proprioceptive stimuli modulate spinal reflexes more than the exteroceptive stimuli. Finally, the cortical processing of such information may in turn modulate spinal reflexes through cortico(-brainstem)-spinal inhibitory pathways onto spinal Ia-dependent inhibitory interneurons [8384].

Secondary outcomes

The combined approach also led to a greater improvement in mood, anxiety, and upper limb motor function (FMA-UE increase), as compared to Armeo-Power practice alone. We may argue that MV plays a key role in improving the gain in motor performance yielded by Armeo-Power practice, regardless of spasticity. This gain in motor performance may in turn improve mood and reduce anxiety. MV can recruit complex networks encompassing premotor-sensory-motor areas [85], thus probably enhancing movement planning, favoring the recruitment of perilesional and neighboring areas, and improving the feedback control of tracking movements, the volume of the available workspace, the movement smoothness, and the inter-joint coordination (which all represent targets of Armeo-Power practice). This may also reduce the abnormal muscle activation coupling [8691], of which we observed a reduction of flexor synergies in favor of extensor synergies in all the patients of group-A and in three subjects of group-B. The decrease in pathologic compensatory strategies may have also contributed to the clinical amelioration. In fact, compensatory strategies have an immediate benefit on daily life activity, but they also have a negative impact on the quality of movement performance and limit the long-term prognosis owing to the learned disuse phenomenon [8691].

Study limitations

The main limitation of our pilot study consists of its underpowered nature. In fact, the required sample size, based on detecting the proportion of patients achieving a minimal detectable change of approximately a one-point decrease on the MAS and a decrease in SICI and HMR of at least 15% (two-tailed test, α level of 0.05, and 80%power), was 30 individuals per group. This limits the significance of multiple comparisons we made, as the required sample size increases linearly with the logarithm of the number of comparisons made [9293]. Even though pilot-study guidelines report that stage-2 clinical rehabilitation pilot studies on physical and cognitive interventions, such as ours, can begin with a convenience sample of at least six participants, we have to be cautious about the inferences that can be drawn from tis underpowered study [94]. Larger samples and crossover studies are necessary to confirm our promising findings.

Other limitations of our study consisted of the lack of a longer follow-up and the relatively high variability of FMA-UE scoring in both groups (slightly more evident in group-B). Such high variability could account for the milder responsiveness of group-B patients to Armeo-Power training alone, while MV allowed group-A patients to meet primary and several secondary outcomes for a longer period, thus strengthening Armeo-Power aftereffects.

Additionally, the improvements observed in those three patients in group-B (“responder” patients, as those belonging to group-A) may question the possibility that the clinical-electrophysiological changes were due to the combination of the interventions, given that they could rather depend on the intensive and repetitive motor activity during Armeo-Power training. However, these group-B “responder” patients had lower FMA-UE and MAS scoring as compared to the other group-B “nonresponder” subjects. Nonetheless, the group-B “responder” patients (as well as the other group-B “nonresponder” subjects) neither showed the corticospinal excitability modulation shown by group-A, nor maintained their outcome improvement at T2 (as instead the patients of group-A did). These issues may confirm that MV is consistently able to strengthen and prolong Armeo-Power effects, probably through both spasticity reduction and corticospinal excitability modulation, beyond primarily facilitating spasticity reduction.

Finally, FIM values are a few below those available in the literature, which however come from patients with a more varying disease duration and mixed stroke etiology than our patients [95100].

Conclusions

Our pilot study suggests that MV combined with Armeo-Power may consistently reduce upper limb spasticity, and strengthen and lengthen the Armeo-Power effects regarding upper limb motor function, mood, and the disability burden. The stronger effect of the combined approach on spasticity and upper limb functions may depend on a sort of associative plasticity between the two coupled trainings, which could have reshaped corticospinal plasticity with a consequent reduction of segmental excitability at the spinal level and an entrainment of recovery processes at the cortical level.

Although larger samples and crossover studies are necessary to confirm our promising findings, we may suggest that MV could be usefully harnessed to increase the functional outcomes obtained by using Armeo-Power, and to improve upper limb spasticity and functions in post-stroke patients.

Suppliers list

  1. a Armeo-Power; Hocoma AG, Switzerland, Industriestrasse 4 CH-8604 Volketswil; Tel. +41434442200, Fax +41434442201; info@hocoma.com; www.hocoma.com.
  2. b Vibraplus; a circle s.p.a., via Ferrara 21–40018 San Pietro in Casale (BO) Italy; tel.: +39051817550—fax: +39051811993.

Supporting information

S1 File. Trial study protocol in English language.

https://doi.org/10.1371/journal.pone.0185936.s002

(DOC)

S2 File. Trial study protocol in Italian language.

https://doi.org/10.1371/journal.pone.0185936.s003

(DOC)

References

  1. 1. Trompetto C, Marinelli L, Mori L, Pelosin E, Currà A, Molfetta L, et al. Pathophysiology of spasticity implications for neurorehabilitation Biomed Res Int 2014;2014:354906. pmid:25530960
  2. 2. Langhorne P, Bernhardt J, Kwakkel G. Stroke rehabilitation Lancet 2011;377:693–1702.
  3. 3. Mehrholz J, Hädrich A, Platz T, Kugler J, Pohl M. Electromechanical and robot-assisted arm training for improving generic activities of daily living arm function and arm muscle strength after stroke. Cochrane Database Syst Rev 2012;6:CD006876
  4. 4. Kwakkel G, Kollen BJ, Krebs HI. Effects of robot-assisted therapy on upper limb recovery after stroke a systematic review Neurorehabil Neural Repair 2008:22:111–121 pmid:17876068
  5. 5. Posteraro F, Mazzoleni S, Aliboni S, Cesqui B, Battaglia A, Carrozza MC, et al. Upper limb spasticity reduction following active training a robot- mediated study in patients with chronic hemiparesis. J Rehabil Med 2014;42:279–281.
  6. 6. Krebs HI, Mernoff S, Fasoli SE, Hughes R, Stein J, Hogan H. A comparison of functional and impairment-based robotic training in severe to moderate chronic stroke a pilot study. Neurorehabilitation 2008;23:81–87. pmid:18356591
  7. 7. Fazekas G, Horvath M, Troznai T, Toth A. Robot-mediated upper limb physiotherapy for patients with spastic hemiparesis a preliminary study. J Rehabil Med 2007;39:580–582. pmid:17724559
  8. 8. Chang WH, Kim YK. Robot-assisted Therapy in Stroke Rehabilitation. J Stroke 2015;15:174–181.
  9. 9. Di Pino G, Pellegrino G, Assenza G, Capone F, Ferreri F, Formica D, et al. Modulation of brain plasticity in stroke a novel model for neurorehabilitation. Nat Rev Neurol 2014;10:597–608. pmid:25201238
  10. 10. Colomer C, Baldoví A, Torromé S, Navarro MD, Moliner B, Ferri J, Noé E. Efficacy of Armeo® Spring during the chronic phase of stroke Study in mild to moderate cases of hemiparesis. Neurologia 2013;28:261–167. pmid:22727271
  11. 11. Gijbels D, Lamers I, Kerkhofs L, Alders G, Knippenberg E, Feys P. The Armeo Spring as training tool to improve upper limb functionality in multiple sclerosis a pilot study. J Neuroeng Rehabil 2011;85:5–13
  12. 12. Merlo A, Longhi M, Giannotti E, Prati P, Giacobbi M, Ruscelli E, et al. Upper limb evaluation with robotic exoskeleton Normative values for indices of accuracy speed and smoothness NeuroRehabilitation 2013;33:523–530. pmid:24037096
  13. 13. Calabrò RS, Russo M, Naro A, Milardi D, Balletta T, Leo A, et al. Who May Benefit From Armeo Power Treatment? A Neurophysiological Approach to Predict Neurorehabilitation Outcomes. PM&R 2016;pii S1934-1482(16)00074-5.
  14. 14. Casale R, Damiani C, Maestri R, Fundarò C, Chimento P, Foti C. Localized 100 Hz vibration improves function and reduces upper limb spasticity- a double-blind controlled study. Eur J Phys Rehabil Med 2014;50:495–504. pmid:24651209
  15. 15. Tavernese E, Paoloni M, Mangone M, Mandic V, Sale P, Franceschini M, Santilli V (2013) Segmental muscle vibration improves reaching movement in patients with chronic stroke A randomized controlled trial. NeuroRehabilitation 32:591–599. pmid:23648613
  16. 16. Murillo N, Valls-Sole J, Vidal J, Opisso E, Medina J, Kumru H (2014) Focal vibration in neurorehabilitation. Eur J Phys Rehabil Med 50:231–242 pmid:24842220
  17. 17. Rodríguez Jiménez S, Benítez A, García González MA, Moras Feliu G, Maffiuletti NA. Effect of vibration frequency on agonist and antagonist arm muscle activity. Eur J Appl Physiol 2015;115:1305–1312. pmid:25613400
  18. 18. Paoloni M, Tavernese E, Fini M, Sale P, Franceschini M, Santilli V, Mangone M. Segmental muscle vibration modifies muscle activation during reaching in chronic stroke: A pilot study. NeuroRehabilitation 2014;35:405–14. pmid:25227540
  19. 19. Seo HG, Oh BM, Leigh JH, Chun C, Park C, Kim CH. Effect of Focal Muscle vibration on Calf Muscle Spasticity: A Proof-of-Concept Study. PM&R 2016;8:1083–1089.
  20. 20. McNickle E, Carson GG. Paired associative transcranial alternating current stimulation increases the excitability of corticospinal projections in humans. J Physiol 2015;593:1649–1666. pmid:25504575
  21. 21. Avanzino L, Pelosin E, Abbruzzese G, Bassolino M, Pozzo T, Bove M. Shaping motor cortex plasticity through proprioception. Cereb Cortex 2014;24:2807–2814. pmid:23709641
  22. 22. Rosenkranz K, Rothwell JC. Differential effect of muscle vibration on intra-cortical inhibitory circuits in humans. J Physiol 2003;551:649–660. pmid:12821723
  23. 23. Noma T, Matsumoto S, Shimodozono M, Etoh S, Kawahira K. Anti-spastic effects of the direct application of vibratory stimuli to the spastic muscles of hemiplegic limbs in post-stroke patients a proof-of-principle study J Rehabil Med 2012;44:325–330 pmid:22402727
  24. 24. Caliandro P, Celletti C, Padua L, Minciotti I, Russo G, Granata G, et al. Focal muscle vibration in the treatment of upper limb spasticity a pilot randomized controlled trial in patients with chronic stroke. Arch Phys Med Rehabil 2012;93:1656–1661. pmid:22507444
  25. 25. Liepert J, Binder C. Vibration-induced effects in stroke patients with spastic hemiparesis-a pilot study. Restor Neurol Neurosci 2010;28:729–735 pmid:21209488
  26. 26. Conrad MO, Scheidt RA, Schmit BD. Effects of wrist tendon vibration on targeted upper-arm movements in post-stroke hemiparesis. Neurorehabil Neural Repair 2011;25:61–70 pmid:20921324
  27. 27. Cordo P, Wolf S, Lou JS, Bogey R, Stevenson M, Hayes J, Roth E. Treatment of severe hand impairment following stroke by combining assisted movement muscle vibration and biofeedback J Neurol Phys Ther 2013;37:194–203. pmid:24232364
  28. 28. Wessel MJ, Zimerman M, Hummel FC. Non-invasive brain stimulation: an interventional tool for enhancing behavioral training after stroke. Front Hum Neurosci 2015;9:265. pmid:26029083
  29. 29. Takeuchi N, Izumi S. Rehabilitation with poststroke motor recovery: a review with a focus on neural plasticity. Stroke Res Treat 2013;2013:128641. pmid:23738231
  30. 30. Nudo RJ. Recovery after brain injury: mechanisms and principles. Front Hum Neurosci 2013;7:887. pmid:24399951
  31. 31. Hara Y. Brain plasticity and rehabilitation in stroke patients J Nippon Med Sch 2015;82:4–13. pmid:25797869
  32. 32. Marconi B, Filippi GM, Koch G, Giacobbe V, Pecchioli C, Versace V, et al. Long-term effects on cortical excitability and motor recovery induced by repeated muscle vibration in chronic stroke patients. Neurorehabil Neural Repair 2011;25:48–60 pmid:20834043
  33. 33. Verhoog MB, Goriounova NA, Obermayer J, Stroeder J, Hjorth JJ, Testa-Silva G, et al. Mechanisms underlying the rules for associative plasticity at adult human neocortical synapses. J Neurosci 2013;33:17197–17208. pmid:24155324
  34. 34. Bragoni M, Broccoli M, Iosa M, Morone G, De Angelis D, Venturiero V, et al. Influence of psychologic features on rehabilitation outcomes in patients with subacute stroke trained with robotic-aided walking therapy. Am J Phys Med Rehabil 2013;92:16–25.
  35. 35. Matsuzaki S, Hashimoto M, Yuki S, Koyama A, Hirata Y, Ikeda M. The relationship between post-stroke depression and physical recovery. J Affect Disord 2015;176: 56–60. pmid:25702600
  36. 36. Karaahmet OZ, Gurcay E, Avluk OC, Umay EK, Gundogdu I, Ecerkale O, Cakci A. Poststroke depression: risk factors and potential effects on functional recovery. Int J Rehabil Res 2017;40:71–75. pmid:28099186
  37. 37. Bartoli F, Lillia N, Lax A, Crocamo C, Mantero V, Carrà G, Agostoni E, Clerici M. Depression after stroke and risk of mortality: a systematic review and meta-analysis. Stroke Res Treat 2013;2013:862978. pmid:23533964
  38. 38. Douven E, Schievink SH, Verhey FR, van Oostenbrugge RJ, Aalten P, Staals J, Köhler S. The Cognition and Affect after Stroke—a Prospective Evaluation of Risks (CASPER) study: rationale and design. BMC Neurol 2016;16:65. pmid:27176617
  39. 39. Bilge C, Koçer E, Koçer A, Türk Börü U. Depression and functional outcome after stroke: the effect of antidepressant therapy on functional recovery. Eur J Phys Rehabil Med 2008;44: 13–8. pmid:18385623
  40. 40. Medical Research Council. Aids to Examination of the Peripheral Nervous System Memorandum. London, UK: Her Majesty’s Stationery Office; 1976.
  41. 41. Gregson JM, Leathley MJ, Moore AP, Smith TL, Sharma AK, Watkins CL. Reliability of measurements of muscle tone and muscle power in stroke patients. Age Ageing 2000;29:223–228. pmid:10855904
  42. 42. Sloan RL, Sinclair E, Thompson J, Taylor S, Pentland B. Inter-rater reliability of the modified Ashworth Scale for spasticity in hemiplegic patients. Int J Rehab Res 1992;15:158–161.
  43. 43. Pandyan AD, Johnson GR, Price CI, Curless RH, Barnes MP, Rodgers H. A review of the properties and limitations of the Ashworth and modified Ashworth Scales as measures of spasticity. Clinical Rehab 1999;13:373–383.
  44. 44. Zariffa J, Kapadia N, Kramer JL, Taylor P, Alizadeh-Meghrazi M, Zivanovic V, et al. Effect of a robotic rehabilitation device on upper limb function in a sub-acute cervical spinal cord injury population. IEEE Int Conf Rehabil Robot 2011;2011: 5975400. pmid:22275603
  45. 45. Lin KC, Hsieh YW, Wu CY, Chen CL, Jang Y, Liu JS. Minimal detectable change and clinically important difference of the Wolf Motor Function Test in stroke patients. Neurorehabil Neural Repair 2009;23:429–434. pmid:19289487
  46. 46. Bohannon RW, Smith MB. Interrater reliability of a Modified Ashworth Scale of muscle spasticity. Phys Ther 1987;672: 206–207.
  47. 47. Orsnes G, Crone C, Krarup C, Petersen N, Nielsen J. The effect of baclofen on the transmission in spinal pathways in spastic multiple sclerosis patients. Clin Neurophysiol 2000;111:1372–1379. pmid:10904217
  48. 48. Kumru H, Kofler M. Effect of spinal cord injury and of intrathecal baclofen on brainstem reflexes. Clin Neurophysiol 2012;123:45–53. pmid:22030139
  49. 49. Angel RW, Hoffmann WW. The H reflex in normal, spastic and rigid subjects. Arch Neurol 1963;8:591–596.
  50. 50. Bakheit AM, Maynard VA, Curnow J, Hudson N, Kodapala S. The relation between Ashworth scale scores and the excitability of the alpha motor neurones in patients with post-stroke muscle spasticity. J Neurol Neurosurg Psychiatry 2003;74:646–648. pmid:12700310
  51. 51. Shaw L, Rodgers H, Price C, van Wijck F, Shackley P, Steen N, Barnes M, Ford G, Graham L, BoTULS investigators. BoTULS: a multicentre randomised controlled trial to evaluate the clinical effectiveness and cost-effectiveness of treating upper limb spasticity due to stroke with botulinum toxin type A. Health Technol Assess 2000;14:1–113.
  52. 52. Fugl-Meyer AR, Jääskö L, Leyman I, Olsson S, Steglind S. The post-stroke hemiplegic patient. 1. A method for evaluation of physical performance. Scand J Rehabil Med 1975;7: 13–31. pmid:1135616
  53. 53. Gladstone DJ, Danells CJ, Black SE. The Fugl-Meyer assessment of motor recovery after stroke: a critical review of its measurement properties. Neurorehabil Neural Repair 2002;16: 232–240. pmid:12234086
  54. 54. Keith RA, Granger CV, Hamilton BB, Sherwin FS. The functional independence measure: a new tool for rehabilitation. Adv Clin Rehabil 1987;1: 6–18. pmid:3503663
  55. 55. Lundgren-Nilsson Å, Tennant A, Grimby G, Sunnerhagen K. Cross-diagnostic validity in a generic instrument: an example from the Functional Independence Measure in Scandinavia. Health Qual Life Outcomes 2006;4:55. pmid:16928268
  56. 56. Žikić TR, Divjak I, Jovićević M, Semnic M, Slankamenac P, Žarkov M, Žikić M. The effect of post stroke depression on functional outcome and quality of life. Acta Clin Croat 2017;53: 294–301.
  57. 57. Donnellan C, Hickey A, Hevey D, O'Neill D. Effect of mood symptoms on recovery one year after stroke. Int J Geriatr Psychiatry 2010;25:1288–95. pmid:21086539
  58. 58. Yuan H, Zhang N, Wang C, Luo BY, Shi Y, Li J, et al. Factors of Hamilton Depression Rating Scale (17 items) at 2 weeks correlated with poor outcome at 1 year in patients with ischemic stroke. Neurol Sci 2014;35: 171–7.
  59. 59. Aben I, Verhey F, Lousberg R, Lodder J, Honig A. Validity of the beck depression inventory, hospital anxiety and depression scale, SCL-90, and hamilton depression rating scale as screening instruments for depression in stroke patients. Psychosomatics 2002;43: 386–93. pmid:12297607
  60. 60. Groppa S, Oliviero A, Eisen A, Quartarone A, Cohen LG, Mall V, et al. A practical guide to diagnostic transcranial magnetic stimulation: report of an IFCN committee. Clin Neurophysiol 2012;123: 858–882 pmid:22349304
  61. 61. Nielsen JE, Jennum P, Fenger K, Sørensen SA, Fuglsang-Frederiksen A. Increased intracortical facilitation in patients with autosomal dominant pure spastic paraplegia linked to chromosome 2p. Eur J Neurol 2001;8:335–359. pmid:11422430
  62. 62. Fukuda TY, Echeimberg JO, Pompeu JE, Garcia-Lucareli PG, Garbelotti S, Okano-Gimenes R, Apolinário A. Root Mean Square Value of the Electromyographic Signal in the Isometric Torque of the Quadriceps, Hamstrings and Brachial Biceps Muscles in Female Subjects. J Applied Res 2010;10:32–39
  63. 63. Rossini PM, Burke D, Chen R, Cohen LG, Daskalakis Z, Di Iorio R, et al. Non-invasive electrical and magnetic stimulation of the brain spinal cord roots and peripheral nerves Basic principles and procedures for routine clinical and research application An updated report from an IFCN Committee Clin Neurophysiol 2015;126:1071–1107 pmid:25797650
  64. 64. Kujirai T, Caramia MD, Rothwell JC, Day BL, Thompson PD, Ferbert A, et al. Cortico-cortical inhibition in human motor cortex J Physiol 1993;471: 501–519 pmid:8120818
  65. 65. Sohn YH, Dang N, Hallett M. Suppression of corticospinal excitability during negative motor imagery. J Neurophysiol 2003;90(4):2303–9. pmid:14534268
  66. 66. Nakamura H, Kitagawa H, Kawaguchi Y, Tsuji H. Intracortical facilitation and inhibition after transcranial magnetic stimulation in conscious humans. J Physiol 1997;498:817–823. pmid:9051592
  67. 67. Ziemann U, Lonnecker S, Steinhoff BJ, Paulus W. The effect of lorazepam on the motor cortical excitability in man. Exp Brain Res 1999a;109:127–135.
  68. 68. Ziemann U, Lonnecker S, Steinhoff BJ, Paulus W. Effects of antiepileptic drugs on motor cortex excitability in humans: a transcranial magnetic stimulation study. Ann Neurol 1996b; 40: 367–378.
  69. 69. Ziemann U, Rothwell JC, Ridding MC. Interaction between intracortical inhibition and facilitation in human motor cortex. J Physiol 1996c;496: 873–881.
  70. 70. Werhahn KJ, Kunesch E, Noachtar S, Benecke R, Classen J. Differential effects on motorcortical inhibition induced by blockade of GABA uptake in humans. J Physiol 1999;517: 591–597. pmid:10332104
  71. 71. Liepert J, Schwenkreis P, Tegenthoff M, Malin JP. The glutamate antagonist riluzole suppresses intracortical facilitation. J Neural Transm 1997;104: 1207–1214. pmid:9503266
  72. 72. Arwert HJ, de Groot J, Van Woensel WW, Rozing PM. Electromyography of shoulder muscles in relation to force direction J Shoulder Elbow Surg 1997;6:360–370 pmid:9285876
  73. 73. Brown SH, Brookham RL, Dickerson CR. High-pass filtering surface EMG in an attempt to better represent the signals detected at the intramuscular level. Muscle Nerve 2010;41:234–239. pmid:19722252
  74. 74. Raez MBI, Hussain MS, Mohd-Yasin F. Techniques of EMG signal analysis: detection, processing, classification and applications. Biol Proced Online 2006;8:11–35. pmid:16799694
  75. 75. Cohen J. Statistical power analysis for the behavioral sciences. Hillsdale: Erlbaum Associates; 1988.
  76. 76. Jarrassé N, Proietti T, Crocher V, Robertson J, Sahbani A, Morel G, Roby-Brami A. Robotic Exoskeletons A Perspective for the Rehabilitation of Arm Coordination in Stroke Patients. Front Hum Neurosci 2014;8: 947. pmid:25520638
  77. 77. Mazzoleni S, Puzzolante L, Zollo L, Dario P, Posteraro F. Mechanisms of motor recovery in chronic and subacute stroke patients following a robot-aided training. IEEE Trans Haptics 2014;7:175–180. pmid:24968381
  78. 78. Mukherjee A, Chakravarty A. Spasticity Mechanisms–for the Clinician. Front Neurol 2010;1:149. pmid:21206767
  79. 79. Trompetto C, Marinelli L, Mori L, Pelosin E, Currà A, Molfetta L, Abbruzzese G. Pathophysiology of spasticity: implications for neurorehabilitation. Biomed Res Int 2014;2014:354906. pmid:25530960
  80. 80. Dietz V, Sinkjaer T. Spastic movement disorder: impaired reflex function and altered muscle mechanics. Lancet Neurol 2007;6:725–33. pmid:17638613
  81. 81. Zarzecki P, Shinoda Y, Asanuma H. Projection from area 3a to the motor cortex by neurons activated from group I muscle afferents. Exp Brain Res 1978;33:269–282. pmid:151631
  82. 82. Radovanovic S, Korotkov A, Ljubisavljevic M, Lyskov E, Thunberg J, Kataeva G, et al. Comparison of brain activity during different types of proprioceptive inputs a positron emission tomography study. Exp Brain Res 2002;143:276–285 pmid:11889505
  83. 83. Dimitriou M, Edin BB. Human muscle spindles act as forward sensory models. Curr Biol 2010;20:1763–1767. pmid:20850322
  84. 84. Lewis GN, Byblow WD, Carson RG. Phasic modulation of cortico-motor excitability during passive movement of the upper limb effects of movement frequency and muscle specificity. Brain Res 2001;900:282–294 pmid:11334809
  85. 85. Arpinar-Avsar P, Park J, Zatsiorsky VM, Latash ML. Effects of muscle vibration on multi-finger interaction and coordination. Exp Brain Res 2013;229:103–111. pmid:23736524
  86. 86. Frisoli A, Procopio C, Chisari C, Creatini I, Bonfiglio L, Bergamasco M, et al. Positive effects of robotic exoskeleton training of upper limb reaching movements after stroke. J Neuroeng Rehabil 2012;9:36 pmid:22681653
  87. 87. Tropea P, Monaco V, Coscia M, Posteraro F, Micera S. Effects of early and intensive neuro-rehabilitative treatment on muscle synergies in acute post-stroke patients a pilot study. J Neuroeng Rehabil 2013;10:103 pmid:24093623
  88. 88. Krabben T, Prange GB, Molier BI, Stienen AH, Jannink MJ, Buurke JH, Rietman JS. Influence of gravity compensation training on synergistic movement patterns of the upper extremity after stroke a pilot study. J Neuroeng Rehabil 2012;9:44. pmid:22824488
  89. 89. Taub E, Uswatte G, Mark VW, Morris DM. The learned nonuse phenomenon implications for rehabilitation Eura Medicophys 2006;42:241–256. pmid:17039223
  90. 90. van Kordelaar J, van Wegen EE, Kwakkel G. Unraveling the interaction between pathological upper limb synergies and compensatory trunk movements during reach-to- grasp after stroke a cross-sectional study. Exp Brain Res 2012;221:251–262. pmid:22791198
  91. 91. Michaelsen SM, Luta A, Roby-Brami A, Levin MF. Effect of trunk restraint on the recovery of reaching movements in hemiparetic patients. Stroke 2001;32:1875–1883. pmid:11486120
  92. 92. Witte JS, Elston RC, Cardon LR. On the relative sample size required for multiple comparisons. Stat Med 2000;19: 369–72. pmid:10649302
  93. 93. Tseng CH, Shao Y. Sample Size Growth with an Increasing Number of Comparisons. J Probability Stat 2012;2012:1–10
  94. 94. Dobkin BH. Progressive Staging of Pilot Studies to Improve Phase III Trials for Motor Interventions. Neurorehabil Neural Repair 2009;23: 197–206. pmid:19240197
  95. 95. Stoykov ME, Lewis GN, Corcos DM. Comparison of bilateral and unilateral training for upper extremity hemiparesis in stroke. Neurorehabil Neural Repair 2009;23: 945–53. pmid:19531608
  96. 96. Toris GT, Bikis CN, Tsourouflis GS, Theocharis SE. Hepatic encephalopathy: An updated approach from pathogenesis to treatment. Medical Science Monitor. Int Med J Exp Clin Res 2012;17:RA53–RA63.
  97. 97. Lin KC, Wu CY, Liu JS, Chen YT, Hsu CJ. Constraint-induced therapy versus dose-matched control intervention to improve motor ability, basic/extended daily functions, and quality of life in stroke. Neurorehabil Neural Repair 2009;23:160–165. pmid:18981188
  98. 98. Hu XL, Tong KY, Song R, Zheng XJ, Leung WW. A comparison between electromyography-driven robot and passive motion device on wrist rehabilitation for chronic stroke. Neurorehabil Neural Repair 2009;23:837–46. pmid:19531605
  99. 99. Lin KC, Chang YF, Wu CY, Chen YA. Effects of constraint-induced therapy versus bilateral arm training on motor performance, daily functions, and quality of life in stroke survivors. Neurorehabil Neural Repair 2009;23:441–448. pmid:19118130
  100. 100. Housman SJ, Scott KM, Reinkensmeyer DJ. A randomized controlled trial of gravity-supported, computer-enhanced arm exercise for individuals with severe hemiparesis. Neurorehabil Neural Repair 2009;23:505–14. pmid:19237734