Simple Detection of the IS6110 Sequence of Mycobacterium tuberculosis Complex in Sputum, Based on PCR with Graphene Oxide

  • Sang-Hyun Hwang ,

    mindcatch@ncc.re.kr

    Affiliations Department of Laboratory Medicine, Center for Diagnostic Oncology, Research Institute and Hospital, National Cancer Center, Goyang-si, Gyeinggi-do, 410–769, Republic of Korea, Hematologic Malignancy Branch, Research Institute and Hospital, National Cancer Center, Goyang-si, Gyeinggi-do, 410–769, Republic of Korea

  • Dong-Eun Kim,

    Affiliation Department of Bioscience and Biotechnology, Konkuk University, Seoul, 143–701, Republic of Korea

  • Heungsup Sung,

    Affiliation Department of Laboratory Medicine, University of Ulsan College of Medicine and Asan Medical Center, 388–1 Pungnap-dong, Songpa-gu, Seoul, 138–736, Republic of Korea

  • Byeong-Min Park,

    Affiliation Department of Laboratory Medicine, Center for Diagnostic Oncology, Research Institute and Hospital, National Cancer Center, Goyang-si, Gyeinggi-do, 410–769, Republic of Korea

  • Mi-Jeong Cho,

    Affiliation Department of Laboratory Medicine, Center for Diagnostic Oncology, Research Institute and Hospital, National Cancer Center, Goyang-si, Gyeinggi-do, 410–769, Republic of Korea

  • Ok-Jin Yoon,

    Affiliation Department of Laboratory Medicine, Center for Diagnostic Oncology, Research Institute and Hospital, National Cancer Center, Goyang-si, Gyeinggi-do, 410–769, Republic of Korea

  • Do-Hoon Lee

    Affiliation Department of Laboratory Medicine, Center for Diagnostic Oncology, Research Institute and Hospital, National Cancer Center, Goyang-si, Gyeinggi-do, 410–769, Republic of Korea

Abstract

Graphene oxide (GO) has proven to be a satisfactory DNA-sensor platform for applications in enzyme-free signal amplification, fluorescence-based amplification, and nanoparticle-based platforms because of its excellent electrical, thermal, and optical properties. In this study, we designed a novel platform for the fluorescence detection of biomolecules, using a fluorescent dye-labeled primer and GO. We applied this system for the detection of the IS6110 insertion sequence of the Mycobacterium tuberculosis complex (MTB) and evaluated its feasibility for use in molecular diagnostics. Fifty-four sputum specimens were collected at our institution from October 2010 to March 2012. To detect MTB in the samples, we performed PCR amplification of the IS6110 DNA sequence using FAM-labeled primers, after which the PCR amplicon was incubated with GO and the fluorescence was measured. The results were compared with those obtained by conventional real-time quantitative PCR (RQ-PCR). The fluorescence intensity observed increased in a concentration-dependent manner with the FAM-labeled IS6110 amplicon. The results of the PCR-GO system for detecting IS6110 DNA were in good agreement with those obtained with conventional RQ-PCR (kappa statistic = 0.925). The PCR-GO system detected MTB DNA in 23 of 25 RQ-PCR-positive sputum samples (92.0%; 95% CI, 75.0–98.0%), but not in 29 of 29 RQ-PCR-negative sputum samples (100%; 95% CI, 88.1–100.0%). These results indicate the utility of the PCR-GO system in molecular diagnostics.

Introduction

Graphene is a one-atom-thick planar sheet of sp2-bonded carbon atoms that forms a honeycomb crystal lattice [1]. Graphene is an attractive nanomaterial because of its unique optical, physical, and electrochemical properties, which make it promising for biosensing applications [2,3] and nucleic acid detection [4,5]. Optically, graphene shows light absorption from the ultraviolet to the near-infrared regions. In addition, graphene is an efficient fluorescence quencher that is useful in the optical-based detection of biomolecules [69]. Graphene oxide (GO) is a water-soluble derivative of graphene that preferentially associates with single-stranded (ss) nucleic acids by π-π stacking interactions, with a lower affinity for double-stranded (ds) nucleic acids [3,10]. Therefore, GO could potentially be used as a fluorescence quencher for the detection of DNA sequences instead of conventional fluorescent probes, such as TaqMan or Molecular Beacon probes. Using GO as a quencher may be advantageous in that it more efficiently quenches fluorescence than other commonly used quenchers. In addition, GO can serve as a universal quencher, in contrast to conventional fluorescent probes such as TaqMan and Molecular Beacon probes, which are FRET-based donor-acceptor (quencher) dye pairs that must be prepared for each target sequence being detected [6].

Tuberculosis (TB) is caused by gram-positive bacteria that are members of the Mycobacterium tuberculosis (MTB) complex, including such human pathogens as M. tuberculosis and M. africanum. TB poses a serious global health threat, with 9 million new cases and 1.5 million deaths reported worldwide in 2013 [11]. Multidrug-resistant (MDR) TB strains, with which patients fail to respond to the first-line drugs isoniazid and rifampin, are spreading rapidly and threaten to undermine the control of TB [12]. Reliable, early, and sensitive diagnosis of the MTB complex is required for the effective treatment of patients and disease control [12]. The sensitivity of sputum-smear microscopy is low, and the culture method, which is generally used to confirm diagnoses made by microscopy, typically takes several weeks due to the slow growth of MTB, although the use of liquid culture media has reduced the time required for MTB detection [13]. Nucleic-acid amplification tests based on methods such as real-time quantitative PCR (RQ-PCR) or isothermal amplification are currently the most promising methods for clinical diagnostics [1417].

In this study, we developed a simple, separation-free method for MTB DNA detection based on the quenching of GO-bound fluorophores. During the amplification step, a 6-carboxyfluorescein (FAM)-labeled primer is incorporated into the amplicon. In the absence of the target, it remains free in solution. Once GO is added, the single-stranded primer adsorbs to GO, resulting in quenching of the FAM fluorescence. Adsorption of the double-stranded amplicon to GO is less favorable; thus, fluorescence is detected in the presence of the target amplicon. A low-cost fluorometer was used for detection purposes. In recent studies, non-amplified single-stranded RNA sequences such as microRNAs were captured and detected using GO [18]. However, we first amplified the target DNA by PCR and then measured the fluorescence from dye-labeled primers that were incorporated into the target amplicons, resulting in desorption from GO and fluorescence signaling. In addition, we evaluated the feasibility of our PCR-GO method for detecting MTB and compared its performance with that of a commercial RQ-PCR test.

Materials and Methods

Sample collection and DNA extraction

We used 54 sputum specimens that had been stored after completing a previous study for MTB detection [19]. Out of the 54 specimens tested, 46.3% (25/54) were MTB-positive. The sputum samples (1 mL) were inactivated by heating at 80°C for 60 min, and 200 μL of each sample was used for DNA extraction with the QIAamp DNA Stool Mini Kit (QIAGEN, Valencia, CA, USA), according to the manufacturer’s instructions.

IS6110 PCR

Gene-specific primers targeting the IS6110 sequence (GenBank Accession No. X52471) were designed with the Primer3 program [20]. The nucleotide sequences of the forward and reverse primers were 5′-FAM-GCCTACGTGGCCTTTGTCAC-3′ and 5′-C3-GTCCAGATGGCTTGCTCGAT-3′, respectively, where C3 is a 3-carbon spacer. The amplicon size was 113 bp. Primers were synthesized by Integrated DNA Technologies (Coralville, Iowa, USA).

Amplification was performed using the HotStarTaq Plus Master Mix Kit (QIAGEN), as described previously [19]. Reaction mixtures contained 0.25 μM of each dNTP, 0.4 μM forward primer, 0.3 μM reverse primer, and 5 μL of sample DNA. A GeneAmp PCR System 9700 thermal cycler (Applied Biosystems, Foster City, USA) was used for DNA amplification. The thermal cycling conditions used were as follows: 5 min at 95°C; 40 cycles at 94°C for 30 s, 65°C for 30 s, and 72°C for 30 s; and 72°C for 10 min. All experiments were performed in duplicate.

For comparison purposes, conventional RQ-PCR was performed using the AdvanSure TB/NTM Real Time PCR Kit (LG Lifesciences, Seoul, Korea) on the ABI Prism 7000 Sequence Detection System (Applied Biosystems), as described previously [19].

For serial dilution sensitivity testing, we generated plasmids containing the IS6110 DNA sequence (p-IS6110) as described previously [19], and a 10-fold dilution series (101–106 copies/ μL) was prepared.

Detection of amplification using GO as a fluorescence quencher

The principle of the GO-based amplification detection system is illustrated in Fig 1. Briefly, after PCR amplification, 20 μL of FAM-labeled PCR amplicon was mixed with 20 μL of 1 mg/mL stock of GO (Graphene Square, Seoul, South Korea) and 60 uL of distilled water for a final GO concentration of 0.2 mg/mL, and the mixture was incubated for 15 min at room temperature. The fluorescence intensities of the samples were measured with the Qubit 2.0 Fluorometer (Invitrogen, Eugene, OR, USA), using the blue LED (max ~470 nm) excitation light source. The fluorescent signals were recorded as relative fluorescent units (RFUs) using a green fluorescence emission filter (510–580 nm), and the RFU (sample)/RFU (control) ratios were calculated.

thumbnail
Fig 1. Illustration describing the GO-based sensing system for homogenous detection of the IS6110 DNA amplicon.

In the presence of the IS6110 DNA amplicon, the fluorescent dye-labeled primers are incorporated into the amplicon causing the primers to separate from GO, leading to increased fluorescence (upper part of the figure). In the absence of the target DNA, the fluorescent dye-labeled primers remain adsorbed to the GO layer, resulting in fluorescence quenching (lower part of the figure).

https://doi.org/10.1371/journal.pone.0136954.g001

Results

The fluorescent signal detected using the PCR-GO system is proportional to the amplicon concentration

As shown in Fig 2, the fluorescence intensity displayed gradual increases with increasing concentrations of fluorescent dye-labeled amplicons.

thumbnail
Fig 2. Fluorescence signaling after PCR-GO is proportional to the amplicon concentration.

Fluorescence in tubes containing 0 (NTC) to 105 copies/reaction of a plasmid encoding the IS6110 sequence is shown. Twenty microliters of a 1 mg/mL stock of GO was added at a final concentration 0.2 mg/mL. The fluorescence images were obtained using the IVIS Lumina Series Ⅲ imaging system. NTC, no-template control.

https://doi.org/10.1371/journal.pone.0136954.g002

Sensitivity assay of PCR-GO detection

To determine the detection sensitivity of the PCR-GO method, the p-IS6110 plasmid was serially diluted and amplified using a primer pair, one of which was FAM-labeled. Subsequently, the PCR amplicons were incubated with GO, after which the fluorescence intensity was measured. The fluorescence intensity at 543 nm and the RFU ratios increased proportionally to the increase in p-IS6110 amplicon concentration (Fig 3).

thumbnail
Fig 3. Detection sensitivity of the PCR-GO system.

Left, The RFU ratios (sample/control) increased in proportion to the concentration of p-IS6110 used for PCR amplification (101–106 copies/reaction). Negative group (no template control) was significantly different from positive groups (101, 102, 103, 104, 105, 106 copies/reaction) (Tukey-Kramer multiple-comparison test, p < 0.05). 10 replicates were performed at each concentration. Right, Gel electrophoresis of the 113-bp amplicons after PCR amplification using 101–106 copies of the p-IS6110 plasmid per reaction, as indicated. Right, C, blank; NC, no-template control.

https://doi.org/10.1371/journal.pone.0136954.g003

Performance of the PCR-GO system with clinical samples

Finally, we evaluated the performance of the PCR-GO system for detecting IS6110 DNA in clinical samples. The results were in good agreement with those obtained using a conventional RQ-PCR kit (kappa statistic = 0.925). The PCR-GO system detected MTB DNA in 23 out of 25 RQ-PCR-positive samples (92.0%; 95% CI: 75.0–98.0%) but not in 29 out of 29 RQ-PCR-negative samples (100%; 95% CI: 88.1–100.0%).

Discussion

In this study, we explored the feasibility of using GO as a DNA biosensor for detecting the IS6110 sequence of MTB and prototyped a PCR-GO detection system for potential applications in molecular diagnostics. We evaluated the performance of the PCR-GO system in comparison to the commercial AdvanSure RQ-PCR kit that is approved for in vitro diagnostics by the Korean Food and Drug Administration. In a previous study, we used this kit to detect TB in 129 culture–positive TB specimens. We found that 82 out of 82 AFB-stain-positive specimens (100%) and 35 of 47 (74.5%) AFB-stain-negative specimens were detected using this kit, indicating a sensitivity of 90.7% and a specificity of 100% [21]. To the best of our knowledge, no previous studies have been performed to compare the PCR-GO method with current clinical molecular-detection techniques. The PCR-GO results showed strong agreement with the results obtained using conventional RQ-PCR (96.3% agreement; kappa = 0.925). The PCR-GO-based fluorometric assay is cost-effective and does not need spectrally matched reporter and quencher dyes, as used in TaqMan assays.

Some MTB strains contain do not encode the target DNA IS6110 sequence in their genomes, and this assay would not be suitable in such cases [22].

One of advantages of GO is that it more efficiently quenches the fluorescence of common fluors. GO can also serve as an effective universal quencher, without the need for designing new dual-labeled probes for each target, as is done with conventional fluorescent probes such as TaqMan and Molecular Beacon probes [69]. Moreover, primers labeled with different fluors in combination with GO as quencher can be used for multiplexing, in contrast to detection via intercalating dyes such as SYBR green that do not enable multiplexing. However, GO could be used for multiplexing if the primers were labeled with different fluors. In addition, the cost per sample of PCR-GO is less expensive. The cost per sample of a FAM-labeled primer was ~$0.2 and that of GO was ~$0.02. In contrast, the cost per sample of dual-labeled probes including a quencher dye was ~$0.7 in this study.

The appropriate design of DNA probes and optimization of GO concentrations was important for improving the specificity of detection of IS6110 DNA based on the GO platform. DNA absorption/desorption from GO is critically affected by salts, pH, temperature, and organic solvents such as ethanol [9,23]. The amplicon and primer/probe sizes have also been shown to affect DNA absorption/desorption from GO [9]. In agreement with previous findings, we observed that fluorescent signal intensities varied according to amplicon sizes (data not shown). The optimal GO concentration for quenching fluorescence emission was found to be 0.2 mg/mL (S1 Fig). Similar concentrations (0.25–0.4 mg/mL) of GO were used in other studies [24,25].

One drawback of our PCR-GO system is that primer-dimers can produce false positive signals. Another disadvantage is that the end point-detection format requires opening of the tube containing amplicon to add the GO. This introduces significant risk of amplicon carryover, and subsequent false positives. Real-time detection formats provide a key advantage in that tubes containing amplicon do not have to be opened up again. However, lab-on-a-chip technologies including microfluidics could add amplicons to the GO in closed system in the future.

However, unresolved issues and technical problems remain, such as optimizing the probe size, as well as the surface modification and structure of GO, which could enhance the performance of the GO-based DNA detection platform. Therefore, further studies should be performed to improve the sensitivity of the PCR-GO system.

The PCR-GO assay was developed using the Qubit 2.0 fluorometer, which is a small, low-cost, easy-to-use analytical instrument for DNA, RNA, and protein quantitation. This fluorometer has 2 light sources (blue and red LEDs), 2 excitation filters (blue: 430–495 nm and red: 600–645 nm), and 2 emission filters (green: 510–580 nm and red: 665–720 nm). FAM has an excitation/emission peak at 495/520 nm. Therefore, we could detect the fluorescence signal from the FAM-labeled primers with the Qubit 2.0 fluorometer.

In conclusion, we developed a novel and simple PCR-GO-based system and demonstrated its application in detecting MTB. In this study, we showed that the performance of our detection system using a simple fluorometer was comparable to that of conventional RQ-PCR. Improvements and optimization of the PCR-GO system are challenges that merit further attention. In the future, biosensors, lab-on-chip technologies, and microfluidics systems are just some of the technologies in which GO-based analysis can be integrated to generate highly sensitive in vitro diagnostic devices.

Supporting Information

S1 Fig. Optimization of the GO concentration for FAM-fluorescence quenching.

https://doi.org/10.1371/journal.pone.0136954.s001

(DOCX)

Author Contributions

Conceived and designed the experiments: SHH DEK HS DHL. Performed the experiments: BMP MJC OJY. Analyzed the data: DHL. Contributed reagents/materials/analysis tools: SHH. Wrote the paper: SHH.

References

  1. 1. Artiles MS, Rout CS, Fisher TS (2011) Graphene-based hybrid materials and devices for biosensing. Adv Drug Deliv Rev 63: 1352–1360. pmid:21867736
  2. 2. Zhang M, Le HN, Ye BC (2013) Graphene oxide-based fluorescent "on/off" switch for visual bioassay using "molecular beacon"-hosted Hoechst dyes. ACS Appl Mater Interfaces 5: 8278–8282. pmid:23968374
  3. 3. Chang H, Tang L, Wang Y, Jiang J, Li J (2010) Graphene fluorescence resonance energy transfer aptasensor for the thrombin detection. Anal Chem 82: 2341–2346. pmid:20180560
  4. 4. Lee J, Park IS, Jung E, Lee Y, Min DH (2014) Direct, sequence-specific detection of dsDNA based on peptide nucleic acid and graphene oxide without requiring denaturation. Biosens Bioelectron 62: 140–144. pmid:24997367
  5. 5. Kang T, Choi H, Joo SW, Lee SY, Yoon KA, Lee K. (2014) Peptide nucleic acid-mediated aggregation of reduced graphene oxides and label-free detection of DNA mutation. J Phys Chem B 118: 6297–6301. pmid:24821658
  6. 6. Dong H, Gao W, Yan F, Ji H, Ju H (2010) Fluorescence resonance energy transfer between quantum dots and graphene oxide for sensing biomolecules. Anal Chem 82: 5511–5517. pmid:20524633
  7. 7. Liu F, Choi JY, Seo TS (2010) Graphene oxide arrays for detecting specific DNA hybridization by fluorescence resonance energy transfer. Biosens Bioelectron 25: 2361–2365. pmid:20299201
  8. 8. Loh KP, Bao Q, Eda G, Chhowalla M (2010) Graphene oxide as a chemically tunable platform for optical applications. Nat Chem 2: 1015–1024. pmid:21107364
  9. 9. Wu M, Kempaiah R, Huang PJ, Maheshwari V, Liu J (2011) Adsorption and desorption of DNA on graphene oxide studied by fluorescently labeled oligonucleotides. Langmuir 27: 2731–2738. pmid:21302946
  10. 10. Park JS, Goo NI, Kim DE (2014) Mechanism of DNA adsorption and desorption on graphene oxide. Langmuir 30: 12587–12595. pmid:25283243
  11. 11. Organization WH (2014) Global Tuberculosis Report 2014. Geneva: WHO.
  12. 12. Zignol M, van Gemert W, Falzon D, Sismanidis C, Glaziou P, Floyd K, et al. (2012) Surveillance of anti-tuberculosis drug resistance in the world: an updated analysis, 2007–2010. Bull World Health Organ 90: 111–119D. pmid:22423162
  13. 13. Wallis RS, Kim P, Cole S, Hanna D, Andrade BB, Maeurer M, et al. (2013) Tuberculosis biomarkers discovery: developments, needs, and challenges. Lancet Infect Dis 13: 362–372. pmid:23531389
  14. 14. Antonenka U, Hofmann-Thiel S, Turaev L, Esenalieva A, Abdulloeva M, Sahalchyk E, et al. (2013) Comparison of Xpert MTB/RIF with ProbeTec ET DTB and COBAS TaqMan MTB for direct detection of M. tuberculosis complex in respiratory specimens. BMC Infect Dis 13: 280. pmid:23786563
  15. 15. Lim J, Kim J, Kim JW, Ihm C, Sohn YH, Cho HJ, et al. (2014) Multicenter evaluation of Seegene Anyplex TB PCR for the detection of Mycobacterium tuberculosis in respiratory specimens. J Microbiol Biotechnol 24: 1004–1007. pmid:24786527
  16. 16. Liu Y, Guo YL, Jiang GL, Zhou SJ, Sun Q, Chen X, et al. (2013) Application of hyperbranched rolling circle amplification for direct detection of mycobacterium tuberculosis in clinical sputum specimens. PLoS One 8: e64583. pmid:23750210
  17. 17. Veigas B, Pedrosa P, Couto I, Viveiros M, Baptista PV (2013) Isothermal DNA amplification coupled to Au-nanoprobes for detection of mutations associated to Rifampicin resistance in Mycobacterium tuberculosis. J Nanobiotechnology 11: 38. pmid:24274610
  18. 18. Zhu D, Zhang L, Ma W, Lu S, Xing X (2014) Detection of microRNA in clinical tumor samples by isothermal enzyme-free amplification and label-free graphene oxide-based SYBR Green I fluorescence platform. Biosens Bioelectron 65C: 152–158. pmid:25461151
  19. 19. Hwang SH, Im SG, Sung H, Hah SS, Cong VT, Lee DH, et al. (2014) Upconversion nanoparticle-based Forster resonance energy transfer for detecting the IS6110 sequence of Mycobacterium tuberculosis complex in sputum. Biosens Bioelectron 53: 112–116. pmid:24135541
  20. 20. Rozen S, Skaletsky H (2000) Primer3 on the WWW for general users and for biologist programmers. Methods Mol Biol 132: 365–386. pmid:10547847
  21. 21. Kim YJ, Park MY, Kim SY, Cho SA, Hwang SH, Kim HH, et al. (2008) [Evaluation of the performances of AdvanSure TB/NTM real time PCR kit for detection of mycobacteria in respiratory specimens]. Korean J Lab Med 28: 34–38. pmid:18309253
  22. 22. Lok KH, Benjamin WH Jr., Kimerling ME, Pruitt V, Lathan M, Razeq J, et al. (2002) Molecular differentiation of Mycobacterium tuberculosis strains without IS6110 insertions. Emerg Infect Dis 8: 1310–1313. pmid:12453362
  23. 23. Huang PJ, Liu J (2012) Molecular beacon lighting up on graphene oxide. Anal Chem 84: 4192–4198. pmid:22489847
  24. 24. Zhang C, Yuan Y, Zhang S, Wang Y, Liu Z (2011) Biosensing platform based on fluorescence resonance energy transfer from upconverting nanocrystals to graphene oxide. Angew Chem Int Ed Engl 50: 6851–6854. pmid:21656878
  25. 25. Alonso-Cristobal P, Vilela P, El-Sagheer A, Lopez-Cabarcos E, Brown T, Muskens OL, et al. (2015) Highly Sensitive DNA Sensor Based on Upconversion Nanoparticles and Graphene Oxide. ACS Appl Mater Interfaces.